Marka | Integra Metering AG (formerly Aquametro) |
Ürün | ARD 20/1221-H2 -IN0,1/RW/RD 20 |
Sipariş kodu | IMP3337787 |
Ağırlık | 5.3 |
Integra Metering AG (formerly Aquametro) - ARD 20/1221-H2 -IN0,1/RW/RD 20 ürününün fiyatını ve teslimat süresini öğrenmek için lütfen sorunuzu bize e-postayla gönderin. Diğer model numaraları için de size tavsiyelerde bulunabiliriz. Alman endüstriyel pazarında sizin için en iyi fiyatı ve teslimat süresini bulmaya çalışıyoruz.
Yalnızca yeni ve orijinal ürünler satıyoruz.
Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls water meter
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
(CONTOIL ® fuel oil meters Reed pulser Pulse value 12.5 ml Nominal diameter: 8 mm With female thread for Kupferrohrverschr. 1/4 " Nominal pressure: PN 25 Maximum permissible temperature: 60 ° C Mounting position: horizontal / vertical Largest flow Qmax. 200 l / h In continuous operation: 135 l / h Error of measurement: 4-200 l / h ± 1% of measured value Pulse value: 0.0125 l)
VZO 15 ... iplikle 40, PN 16
oil meter Nominal width: DN 20 mm With flanges DN 20 according to: DIN 2501 Overall length: 165 mm Nominal pressure: PN 25 bar Maximum allowable temperature: 130 ° C Mounting position: horizontal / vertical Largest flow Qmax. 1,500 l / h In continuous operation Qn:. 1,000 l / h Minimum flow Qmin. 30 l / h Error of measurement: 30 - 1,500 l / h ± 1% of measured value Repeatability equal / better than: 0.2% Total amount on roller: 10 million liters Smallest readable Quantity: 0.1 l
yağ sayacı
[AMBUS IS M-Bus Impulssammler 1 Impulseingang 2 Leiter M-Bus Schnittstelle 2 Leiter Energieversorgung aus AMBUS ZS oder Net]
PMG 32-RH1 6.0_260_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 260 mm Mounting position: horizontal Temperature: max. 130 ° C Nominal pressure: PN 16 Minimum flow qi: 0,075 m³ / h Continuous flow qp: 6 m³ / h Maximum flow qs: 12 m³ / h Kvs-value: 12.7 m³ / h Pressure loss at qp: 0,22 bar Pulse value: 1 liter / pulse Environmental class C according to EN 1434 no inlet: 0 x DN 32 no outlet flow: 0 x DN 32 Approval MI-004
Size: DN 32 with thread 1 1/2 "(for screw 1 1/4") Nominal pressure: PN 16 bar length: 150 mm Mounting position: vertical falling temperature max .: 130 ° C Maximum flow qs: 6.3 m3 / h Nominal flow qp: 5 m3 / h minimum flow qi: 0.1 m3 / h pulse value: 1 l Smallest readable amount: 0.1 l registrable: 99,999 m3 measuring principle: multi-jet impeller, dry running With CE marking
PMGS 32-RH1 5.0_150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical ascending Riser counter Temperature: max. 130 ° C Nominal pressure: PN 16 Minimum flow qi: 0.1 m³ / h Continuous flow qp: 5 m³ / h Maximum flow qs: 6,3 m³ / h Kvs-value: 13.6 m³ / h Pressure loss at qp: 0,14 bar Pulse value: 1 liter / pulse Environmental class C according to EN 1434 no inlet: 0 x DN 32 no outlet flow: 0 x DN 32 Approval MI-004
MeiStream RUBIN Kaltwasserzähler Nenngrösse: DN 50 Flanschanschluss: EN 1092-1 Nenndruck: PN 16 bar Baulänge: 200 mm Einbaulage: horizontal/vertikal Schutzart: IP 68 Temperatur max.: 50°C Überlastungsdurchfluss Q4: 90 m3/h Dauerdurchfluss Q3: 50 m3/h Übergangsdurchfluss Q2: 0.4 m3/h Kleinster Durchfluss Q1: 0.15 m3/h Kleinste ablesbare Menge: 0.5 l Registrierfähigkeit: 1 Mio m3 Messprinzip: Woltman-Turbine Messbereich Lieferkennzeichnung: R 100
PMW-basic 32 10._260_1 G1 / 4; Multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 260 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 12.7 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001
PMWF-basic 32 10._150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 10.3 m³ / h Pressure loss in Q3: 900 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001
PMW-basic 16._300_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Thread connection: G 1 " Nominal size: DN 40 Mounting length: 300 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.16 m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 25.6 m³ / h Pressure loss in Q3: 400 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
PMWS-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical ascending Riser counter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 20.8 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
PMWF-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 22.2 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
CE test water meter R49 DN15-32
CE test water meter R49 DN40-50
System module aquapuls® For retrofitting aquabasic® cold water meters. Pulse value 1 l / pulse with return compensation. Switching capacity 220 mA / 48 VDC. Degree of protection IP 68 with 1.5 m cable, fixed. With battery power
DOMINO ® ARD structure group - Reguliergetriebe - Roller 6 digits, with RV Reed pulser, 48 VAC / DC, 50 mA, 2 W Specifications: Recording capacity Roller: 107 l Smallest readable Quantity: 0.1 l Pulse Value: 1 l
Akaryakıt Ölçer
CONTOIL® oil meter VZO 20 RC 130/16-RV 1 Ring piston meter for mineral oil, with rotatable roller counter
P/N 92280 Aquametro Oil Meter
VZO 25 FL 180/JIS 10-20K